Why do you think that Reynobond FR was utilised (as opposed to Reynobond PE).

Viewing the footage of the fire I would have thought it highly likely that the panels were the base range PE version as opposed to the "more expensive" fire retardant option . . .


-----Original Message-----
From: systemsafety [mailto:systemsafety-bounces at lists.techfak.uni-bielefeld.de] On Behalf Of Peter Bernard Ladkin
Sent: 23 June 2017 07:13
To: The System Safety List
Subject: [SystemSafety] Reynobond panelling

There seems to be increasing concern about aluminium composite cladding as building material, e.g., https://www.theguardian.com/uk-news/2017/jun/22/tower-block-cladding-posing-danger-to-thousands-of-residents
. Obviously it is a major concern in the wake of the Grenfell Tower fire.

Many of the initial press articles were indirectly hinting that the panelling was the "cheap stuff", for example that polyethelene-core panelling was used instead of the mineral-wool-core version to save less than £5,000. It would be well to dispel this impression - I think it is mistaken.

Reynobond panelling is produced by a major company, Alcoa, and used throughout the world on large buildings. Reynobond is a registered trade mark in the US of Alcoa. Here is the marketing brochure:
https://www.arconic.com/aap/north_america/catalog/pdf/brochures/Reynobond_Brochure.pdf . It gives some specs, and illustrates six different attachment methods.

A key point is the way the panels are used, in particular the attachment. There is a short description here: https://www.arconic.com/aap/north_america/catalog/pdf/brochures/reynobond_fr.pdf
Note in particular 1.03A: "Shop drawings shall show panel system including attachment methods, joinery, sealing methods and accommodation of thermal movement. Details shall not be drawn less than one-half size."

Details of how to go about installing the panels are given in
-- 

PBL

Prof. Peter Bernard Ladkin, Bielefeld, Germany MoreInCommon Je suis Charlie
Tel+msg +49 (0)521 880 7319  www.rvs-bi.de





********************************************************************
This email and any attachments are confidential to the intended
recipient and may also be privileged. If you are not the intended
recipient please delete it from your system and notify the sender.
You should not copy it or use it for any purpose nor disclose or
distribute its contents to any other person.
********************************************************************


More information about the systemsafety mailing list